Art.-No. 45705

fischer stand-off installation TherMax 10/160 M10

Top Features
  • No thermal bridge due to the anti-cold cone.
  • Installation without setting tool. This saves time.
  • Self-milling plastic cone.
  • Exact alignment of the attachment without pressure marks and damage to the ETICS.
  • Suitable for all building materials.

Las ventajas / descripción del producto

The thermally separated stand-off installation in external thermal insulation composite systems (ETICS).
Advantages
  • The stand-off installation allows for the fixture to be adjusted to the exact position required, whereby pressure marks and damage to the ETICS are avoided.
  • The plastic cone creates a thermal barrier between the fixture and the inner fixture, and offers an energy-optimised fixing.
  • The glass-fibre-reinforced plastic cone cuts its own way through the ETICS with a positive fit, and allows for a simple and fast installation without the need for any special tools.
  • Combining with the universal plug UX provides a secure anchoring in the substrate.
  • Without UX plug direct mounting in wood substrate is possible after pre-drilling.
The fischer stand-off insulation system TherMax 10 is a solution for fixing into external walls without a thermal bridge in ETICS. The stud screw with the glass-fibre reinforced cone cuts its own way through the plaster into the insulation. During mounting, the stud screw is rotated into the universal fixing UX and is therefore secured within the building material. The anti-cold cone at the tip of the stud screw creates a thermal barrier and holds the outer fixing. The TherMax fixes light loads such as lights, letterboxes, or lightning conductors to concrete, aerated concrete, and masonry from solid and perforated brick.
Youtube VideoYoutube VideoYoutube Video

Solicitud y aprobación

Applications
For the thermally separated fixing of:
  • Signs
  • Lighting
  • Letter boxes
  • Motion detectors
  • Downpipes
  • Lightning rods
  • Blind guide rails
Building materials
  • Concrete
  • Vertically perforated brick
  • Hollow blocks made from lightweight concrete
  • Perforated sand-lime brick
  • Solid sand-lime brick
  • Building brick
  • Aerated concrete
  • Wood
* Puede encontrar información detallada sobre materiales de construcción en el documento de registro.

Instrucciones de montaje

Functioning
  • The TherMax 10 system is suitable for pre-positioned installation.
  • The self-tapping, glass-fibre-reinforced cone cuts its own way through the plaster into the insulation during installation.
  • The anti-cold cone uses a thermal barrier to minimise heat losses.
  • Installation without any special tools.
  • For use in wood without plug, the wood (footnote below load table) as well as the plaster has to be pre-drilled: TherMax 10: d02 = 18 mm, h02 = 50 mm.
  • The range features fitting options with metric screws M6/8/10, sheet screws 6.3 mm, chipboard screws 6.0 mm or chipboard screws 4.5 - 5.5 mm when using a SX Plus 5 plug.
Installation in masonry
1 / 8
Installation in wooden substrate
1 / 6

Datos técnicos

Drill diameter (
d0
)
12 mm
Drill hole depth (
h0
)
220 mm
Usable length (
e
)
140 - 160 mm
Anchorage depth (
hef
)
70 mm
Cover cap-ø (
ADK
)
22 mm
Width across nut 13 mm
Chipboard / metric / sheet metal screw M10
Packaging Folding box
Amount 20 St.
GTIN (EAN-Code) 4006209457054

Documentos para descargar

  • Technical documents
  • Sales materials
Stand-off installation TherMax 8 and 10 - Recommended loads of a single anchor in concrete and masonry.
Stand-off installation TherMax 8 and 10 - Recommended tensile loads for a single anchor in wood.
Stand-off installation TherMax 8 and 10 - Recommended shear loads for a single anchor.
cd-green-58bb58464c-46z77